This is a SEO version of Clean Burn 4x9 Brochure 2012. Click here to view full version
« Previous Page Table of Contents Next Page »es
Model CB-2500
*Maximum BTU/hour
250,000 (73 kW)
*Maximum oil consumption
1.7 GPH (6.4 L/h)
Fuels
Used oils Crankcase, ATF, hydraulic Fuel oils #2, #4, and #5 fuel oil
Air flow output (CFM)
Unit heater 2700 Central furnace (ducted) 0.25 SPWC (in.) 2500 0.40 SPWC (in.) 2400
*Air compressor req’d
2.0 CFM @ 20 PSI (3.4 m3/h @ 1.4 bar)
Stack size
8 inch dia. (203mm dia.)
Furnace dimensions, assembled
103.25” L x 29.25 W x 31.5 H (2623mm x 743mm x 787mm)
Approx. weight (uncrated)
509 pounds (229.1 kg)
Electrical requirements
115 VAC 60 Hz, single phase 30 A circuit breaker
The larger of the four low profile models, the Model CB-2500 used-oil furnace is rated at approximately 250,000 BTU/hr. Popular at facilities with multiple bays. UL listed for use as a unit heater or central (ducted) furnace.
Model CB-1750
175,000 (51.25 kW)
1.2 GPH (4.54 L/h)
Fuels
Used oils Crankcase, ATF, hydraulic Fuel oils #2, #4, and #5 fuel oil
Air flow output (CFM)
Unit heater 1700 Central furnace (ducted) 0.25 SPWC (in.) 1500 0.30 SPWC (in.) 1400
Stack size
8 inch dia. (203mm dia.)
Furnace dimensions, assembled
83” L x 29.25 W x 31.5 H (2190mm x 743mm x 787mm)
Approx. weight (uncrated)
406 pounds (182.7 kg)
Electrical requirements
115 VAC 60 Hz, single phase 20 A circuit breaker
*Maximum BTU/hour
*Maximum oil consumption
*Air compressor req’d
2.0 CFM @ 20 PSI (3.4 m3/h @ 1.4 bar)
The Clean Burn Model CB-1750 is rated at approximately 175,000 BTU/hr. Low profile design for convenient installation. UL listed for use as a unit heater or central (ducted) furnace.
Family of Clean Burn Furnaces & Boilers
www.CleanBurn.com
9
Specifcations are subject to change without notice.
r Clean Burn low odel CB-3250 ted at 00 BTU/hr. UL it heater or central
r
umption
, ATF, hydraulic #5 fuel oil
M)
ted) 0 0
q’d
ia.)
s, assembled
5 H 889mm)
crated)
g)
ents
le phase
le phase
ls
d oils Crankcase, ATF, hydraulic l oils #2, #4, and #5 fuel oil
flow output (CFM)
t heater 2000 al fan nace cannot be ducted
*Air compressor req’d
2.0 CFM @ 20 PSI (3.4 m3/h @ 1.4 bar)
Stack size
6 inch dia. (152.4mm dia.)
Furnace dimensions, assembled
45” L x 28 W x 20 H (1143mm x 711.2mm x 508mm)
Approx. weight (uncrated)
300 pounds (136.07 kg)
Electrical requirements
115 VAC 60 Hz, single phase 20 A circuit breaker
This is a SEO version of Clean Burn 4x9 Brochure 2012. Click here to view full version
« Previous Page Table of Contents Next Page »