Page 9 - Clean Burn 4x9 Brochure 2012

This is a SEO version of Clean Burn 4x9 Brochure 2012. Click here to view full version

« Previous Page Table of Contents Next Page »

Furna

Model CB-3500

The Clean Burn Model CB-3500 is rated at approximately 350,000 BTU/hr. Designed for easy installation and convenient service. UL listed for use as a unit heater or central (ducted) furnace.

74” L x 35 W x 61 H (1880mm x 889mm x 1549mm)

*Maximum BTU/hour

350,000 (102 kW)

*Maximum oil consumption

2.5 GPH (9.5 L/h)

Fuels

Used oils Crankcase, ATF, hydraulic Fuel oils #2, #4, and #5 fuel oil

Air flow output (CFM)

Unit heater 4200 Central furnace (ducted) 0.25 SPWC (in.) 4000 0.40 SPWC (in.) 3800

*Air compressor req’d

2.0 CFM @ 25 PSI (3.4 m3/h @ 1.7 bar)

Stack size

8 inch dia. (203mm dia.)

Furnace dimensions, assembled

Approx. weight (uncrated)

850 pounds (385 kg)

Electrical requirements

230 VAC 60 Hz, single phase 30 A circuit breaker

Model CB-5000

*Maximum BTU/hour

500,000 (146 kW)

*Maximum oil consumption

3.6 GPH (13.6 L/h)

Fuels

Used oils Crankcase, ATF, hydraulic Fuel oils #2, #4, and #5 fuel oil

Air flow output (CFM)

Unit heater 5500 Central furnace (ducted) 0.25 SPWC (in.) 5200 0.40 SPWC (in.) 5000

*Air compressor req’d

2.0 CFM @ 25 PSI (3.4 m3/h @ 1.7 bar)

Stack size

10 inch dia. (254mm dia.)

Furnace dimensions, assembled

78” L x 38 W x 73 H (1981mm x 965mm x 1845mm)

Approx. weight (uncrated)

1036 pounds (466.2 kg)

Electrical requirements

230 VAC 60 Hz, single phase 30 A circuit breaker

The Model CB-5000, our largest furnace, is rated at approximately 500,000 BTU/hr. Popular at facilities with multiple bays. UL listed for use as a unit heater or central (ducted) furnace.

Meet the Used-Oil

8

* Values indicated above are nominal. Actual values will vary depending on fuel and installation.

Model CB-325

The largest of the fo profile models, the used-oil furnace is r approximately 325, listed for use as a u (ducted) furnace.

*Maximum BTU/ho

325,000 (95.3 kW)

*Maximum oil con

2.1 GPH (7.91 L/h)

Fuels

Used oils Crankcas Fuel oils #2, #4, an

Air flow output (C

Unit heater 3300 Central furnace (du 0.25 SPWC (in.) 31 0.40 SPWC (in.) 29

*Air compressor r

2.0 CFM @ 20 PSI (3.4 m3/h @ 1.4 bar

Stack size

8 inch dia. (203mm

Furnace dimensio

121” L x 31.25 W x (3073mm x 794mm

Approx. weight (u

641 pounds (288.7

Electrical require

115 VAC 60 Hz, sin 30 A circuit breaker -or-230 VAC 60 Hz, sin 20 A circuit breaker

Model CB-140

The Clean Burn Model CB-140 is the smallest and most economical Clean Burn used-oil furnace in terms of initial cost. It produces approximately 140,000 BTU/hr. and is ideal for small garages, shops, and workspaces.

*Maximum BTU/hour

140,000 (41 kW)

*Maximum oil consumption

1.0 GPH (3.8 L/h)

Fu

Us Fu

Ai

Un Ax Fu

Page 9 - Clean Burn 4x9 Brochure 2012

This is a SEO version of Clean Burn 4x9 Brochure 2012. Click here to view full version

« Previous Page Table of Contents Next Page »